Blog

How to Calculate Gluten Index and Wet Gluten: Formulas, Method and Worked Examples

To calculate the gluten index of wheat flour, divide the wet gluten that stays on the sieve after centrifuging by the total wet gluten, then multiply by 100. Wet gluten itself is the mass of washed gluten as a percentage of the flour sample. Both values come from one test, and together they tell a miller how much gluten a flour has and how strong it is.

This guide explains the formulas, the standard methods (ICC Draft Standard No. 192 and AACC International Method 38-12.02), a fully worked example, and what the results mean for bread, biscuit, pasta and maida flours.

What is gluten index and what is wet gluten?

Wet gluten is the rubbery protein network left after flour is mixed with salt water and the starch is washed away. It tells you the quantity of gluten in the flour.

Gluten index tells you the quality (strength) of that gluten. After washing, the gluten ball is spun in a centrifuge through a fine sieve. Strong gluten holds together and stays on the sieve; weak gluten is pushed through. The gluten index is the share that stays on the sieve, on a scale of 0 to 100.

Two flours can have the same wet gluten content but very different gluten index values. That is why mill labs measure both.

Gluten index formula

Total wet gluten = the gluten remaining on the sieve + the gluten that passed through it. Both parts are weighed after centrifuging.

Wet gluten formula (how to calculate wet gluten)

 

With the standard 10 g sample, simply multiply the wet gluten mass by 10. Many specifications ask for the result on a 14% moisture basis, so correct it with the flour's moisture content (M, in %):

Dry gluten and water-binding capacity

Dry gluten is the wet gluten after it has been dried until all its water is removed. It is calculated the same way:

The difference between the two shows how much water the gluten holds, which matters for dough yield:

Wet gluten vs dry gluten: the difference

 

Wet gluten

Dry gluten

What it is

Washed gluten still holding water

The same gluten after drying

What it shows

Gluten quantity as used in dough

Gluten protein mass without water

Typical size

About 3 times the dry value

About one-third of the wet value

Standard

ICC Draft Standard No. 192; AACC International 38-12.02 (mechanical) and 38-10.01 (hand washing)

ICC Draft Standard No. 192; AACC International 38-12.02

Equipment

Gluten washer + centrifuge

Gluten dryer

How to test wet gluten and gluten index (ICC Draft Standard No. 192 and AACC International 38-12.02)

The mechanical method follows ICC Draft Standard No. 192 (wet gluten, gluten index and dry gluten of wheat flour and whole wheat meal using Bastak devices) and AACC International Method 38-12.02. In short:

  1. Weigh the sample. Weigh 10.00 g of flour (or ground wheat) into the washing chamber fitted with the sieve.
  2. Add salt solution. Add 4.8 mL of 2% sodium chloride solution.
  3. Mix the dough. The instrument mixes the flour and salt water into a dough for about 20 seconds.
  4. Wash out the starch. The dough is washed with salt solution for about 5 minutes until only gluten remains.
  5. Centrifuge. Place the gluten ball in the gluten index sieve cassette and spin it in the centrifuge at 6000 rpm for 1 minute.
  6. Weigh both parts. Weigh the gluten that passed through the sieve and the gluten that stayed on it. Their sum is the total wet gluten.
  7. Dry (optional). Dry the total gluten to get dry gluten and water-binding capacity.

Hand washing (AACC International Method 38-10.01) is still used in some labs, but results depend on the operator. A mechanical gluten washer gives the same washing time, water flow and pressure on every test, so results can be compared between shifts and between labs.

Worked example: calculating gluten index and wet gluten

A 10.00 g flour sample with 13.2% moisture gives these weights:

Measurement

Value

Gluten remaining on the sieve

2.62 g

Gluten passed through the sieve

0.43 g

Total wet gluten

3.05 g

Dry gluten

1.02 g

  • Gluten index = 2.62 ÷ 3.05 × 100 = 85.9, reported as 86
  • Wet gluten (as is) = 3.05 ÷ 10.00 × 100 = 30.5%
  • Wet gluten, 14% moisture basis = 30.5 × (100 − 14) ÷ (100 − 13.2) = 30.2%
  • Dry gluten = 1.02 ÷ 10.00 × 100 = 10.2%
  • Water-binding capacity = (3.05 − 1.02) ÷ 1.02 × 100 = 199%

This flour has a good gluten quantity and strong, elastic gluten: a typical profile for bread flour.

What do the results mean? Typical values

The ranges below are common industry guides. Your own product specifications and customer requirements always come first.

Flour use

Wet gluten (14% mb)

Gluten index

Bread and bakery flour

about 28–35%

about 60–90

Biscuit, cake and cracker flour

about 20–26%

lower, often below 60

Pasta (durum semolina)

about 28% and higher

high, often above 80

General purpose / maida

about 26–32%

about 50–85

Low gluten index flour (below about 50) has weak, extensible gluten. It suits soft products such as biscuits and cakes, but bread made from it can spread and lose volume. A very high gluten index (above about 95) means tight, strong gluten that can be hard to work and may need blending or improvers.

Speed up your gluten testing with Bastak

Manual washing and separate weighing take time and leave room for error. Bastak's gluten testing line covers every step of the method above:

  • Gluten Touch is a touch-screen gluten washer that washes the gluten automatically, with programmable mixing and washing times.
  • Gluten Cheq 6100 is a gluten washing system that washes 2 samples in parallel in about 5 minutes.
  • Centrifuge Cheq 2100 spins the gluten through the sieve cassette to give the gluten index.
  • Dry Cheq 2500 dries the wet gluten for dry gluten and water-binding capacity.

See the full range of flour and grain quality control equipment, or contact our team for a quote and a demonstration in your lab.

Related reading: more guides on flour quality, NIR grain analysis and protein testing on the Bastak blog.

Frequently asked questions

How do you calculate gluten index? Divide the wet gluten remaining on the sieve after centrifuging by the total wet gluten, and multiply by 100. For example, 2.62 g ÷ 3.05 g × 100 = 86.

What is the wet gluten formula? Wet gluten (%) = total wet gluten (g) ÷ sample mass (g) × 100. With a 10 g sample, multiply the gluten mass by 10.

What is the difference between wet gluten and dry gluten? Wet gluten still contains water and shows gluten quantity as it behaves in dough. Dry gluten is the same gluten after drying and is usually about one-third of the wet value.

Which standards cover gluten testing with Bastak instruments? ICC Draft Standard No. 192 (2023) covers determining the wet gluten, gluten index and dry gluten of whole wheat meal and wheat flour using Bastak devices. The matching AACC International method is 38-12.02, and hand washing is covered by AACC International Method 38-10.01.

What is a good wet gluten value for maida? Maida used for bread and bakery products usually has about 26–32% wet gluten. In India, FSSAI also sets a minimum dry gluten content for maida, so check the current FSSAI standard and your buyer's specification.

What does a low gluten index mean? A low gluten index means weak, extensible gluten. It is suitable for biscuits and cakes but may give low bread volume.

Can I measure gluten index without a centrifuge? No. The gluten index method depends on spinning the gluten through a standard sieve at a fixed speed, so a gluten index centrifuge is required.